Introduction

This guide will teach you how to replace the metal needle plate on the Brother CS6000i. You will need a Phillips #2 screwdriver as well as a 4mm flathead screwdriver. It will take about 15-20 minutes.

  1. gHBCqmQxl1xlTgNJ
    gHBCqmQxl1xlTgNJ
    4brVwmOqhKKA2aEh
    • Remove the five 20 mm Phillips #2 screws on the back of the device.

    • Remove the single 28 mm Phillips #2 screw on the back of the device.

    • Remove the single 23 mm Phillips #2 screw on the back of the device.

  2. khTF4unDjLUHG6BN
    khTF4unDjLUHG6BN
    2bMLWSYLw5hesvYu
    • Pull the white cover off.

  3. OGYPMEXYdaphgvaY
    OGYPMEXYdaphgvaY
    12Gjhy3HEOKUDOxC
    • Remove the final screw, a 11 mm Phillips #2.

    • After removing all eight screws, you will have five 2 mm screws, one 28 mm screw, one 23 mm screw, and one 11 mm screw, all of which are Phillips #2.

  4. e4rhLwRchXLjZdDZ
    e4rhLwRchXLjZdDZ
    hHiGEOVBCiCa2NCm
    CB63ku3eqSjJwsf6
    • Slightly pull apart the two halves of the machine, taking care not to strain the attached cables.

    • Unhook the white wires that are connected to the motherboard.

    • Fully separate the two halves.

  5. TDBDUpEVVN1rECQV
    TDBDUpEVVN1rECQV
    kWSmfxkxVLY2b4Oh
    • Remove the two screws securing the needle plate with a 4mm flathead screwdriver.

Conclusion

To reassemble your device, follow these instructions in reverse order.

Ava Martinez

Member since: 31/10/24

433 Reputation

0 comments